- Overview
-
Nuheat Cable is an Electric Radiant Floor Heating system that allows contractors to instantly make on-site adjustments to the floor heating coverage for any room including those with curves and angles. While an alternative to Nuheat Mats, cables take more time, effort and thought than Nuheat Mats since you customize the layout as you go.
Nuheat Cable offers installation flexibility since you lay out the Cable to fit the floor area. Available in both 120V and 240V, the Nuheat Cable System is only 3/16' thick making it ideal for both remodeling and new construction projects.
Nuheat describes their cable kits with a size Range (Examples: 4 - 8 SF or 89-100 SF) but the cable cannot be lengthened or shortened. The spacing between cable runs should always be 3 throughout the entire installation (3' is the ONLY spacing Nuheat allows) so be sure to choose the correct kit for your size floor (you can use more than one per room).
- Product Details
Width of heating area Feet Variable - you determine layout width, length, shape Length of heating area Feet Variable - you determine layout width, length, shape Heated Area 19 SF (Sq. Ft. Square Feet) Length of heating area inches 828" in. inches Mat Style Heating Cable secured to floor using Metal Cable Strap (track). Strap secured to floor with tape,screws or glue Custom Mat Options None. Standard lengths only. No customization Safety Listed in USA & Canada : UL 1693 & CAN/CSA C22.2 No. 130-03 ETL Listed for U.S. and Canada : Listing file number: 3151992 Packaging Easy Open Cardboard - no frustration. Easy to dispense wire from box Color No WarmWire Strap Qty to Order Straps are included in the kit Acceptable Floor Coverings Tile, Stone,Granite, Marble, Slate, Engineered wood, Laminate Made In USA Made in Canada from a majority of USA components. - How to Install
Patented Nuheat Cable Guides (included in each kit) are first secured onto the subfloor around the perimeter of the room. The Nuheat Cable Guides are superior to other clips or straps provided with other floor heating cable products as they are made of durable yet flexible plastic and lay flat on the subfloor to guarantee the lowest profile.
The heating cable is then installed and covered with thinset mortar or floor leveling cement (aka self-leveler). After the mortar has cured flooring can then be installed on top of this new layer.
You can use the Layout Assistant Chart to determine how far from the walls you install the cable to heat the area, generally 1 to 6 inches in from the perimeter of the heated area
Nuheat Cable may also be installed in combination with the Nuheat Mat system. Both systems have leads and can be wired together to the same thermostat. So you can use Standard mats for rectangular or square areas and fill in with cables for the irregular angled or curved portions of your room.
Nuheat Cable Instruction Manual /media/Nuheat-Cable-Installation-Manual-Current.pdf Nuheat Cable Installation Video Maximum Circuit Load 15 Amps Maximum Circuit Overload Protection 20 A Breaker. GFCI Protection Required (Ground Fault Circuit Interrupter) Required for each circuit - INCLUDED in Nuheat Control Circuit Breaker & supply wire Recommended (must follow local codes) See chart Electrical Box Size (Where Mats connect to Thermostat) Extra-deep single-gang box for 1 or 2 leads, Or 4" square deep box for 3 cables (extra room needed for Wire, wire nuts, control) Heating Elements (Dual Wire) Oxygen-free copper or nickel-copper Full Length End-to-End ground wire Yes. Heating Wire Insulation wire construction Copper/Copper Alloy Heating wire insulated with ETFE and surrounded with protective Stainless steel ground shield. Repairable Heating Wire Yes, Wire can be repaired. Repair kits and assistance available. Expected Floor Temperature Dependent on Many factors, insulation recommended. Read More Skill Level : D-I-Y Simple for Install, PRO for Electric Running Cable more difficult + more time than MATS. Installation only by qualified persons. Electrician recommended for wiring. Read More Shower Installation Permitted (USA) Yes, can be installed in a tiled shower. Read More Installation Layout Map customized for my project Yes - see examples. We provide Layout Maps only for MATS Insulation Recommended Yes; under slabs or framed floors. Cork or similar on top of Concrete Subfloor as thermal break Indoor Installation Only INTERIOR floor heating Application only. Embedded in Mortar only Installation On Sub Floor on TOP of Sub Floor (Plywood, backer board, concrete) Distance from Wax Ring at toilet flange install 4 - 6 inches away; can be under front of toilet. Approx 20" from wall Trowel Size recommended minimum 3/8" x 1/4". Works for most ceramic tile; verify with tile/mortar manufacturer Trowel type Recommended Heavy Duty Plastic PRO-Trowel Minimum Bend Radius 1" inch Cut Warning No. Never cut the heating elements to shorten Minimum Installation Temperature 50 Degrees F / 10 Degrees C - Specifications
Voltage 120 VAC How to choose 120 or 240 Volt Same Energy efficiency & same Watts/SF. More Sq Footage per circuit with 240v Amp Draw (this Mat) 0.9 Watts Per SF 12 Watts per Sq Foot Wattage : total watts for this mat 207 watts Heat Output BTUs per SF 41 BTU per Sq Ft/Hour Heating Power : Total BTU's 779 BTU total Manufacturer Nuheat Industries Ltd. Brands Nuheat Power Lead Type TEW Wire with Stainless Steel ground braid rated to 105 C and 300v max. Power Lead Length 10 Feet Power Lead Wire Gauge (varies by heated area) 14 AWG Warranty from Manufacturer 25 years Product Thickness 3/16" or a little more Heating Wire Spacing within Mat 3" on center only Weight 5.0000 Ohms Reading (resistance value) for Wht/Blk or Blue/Blk wires 279 ZERO* EMF (Electro Magnetic Field) Tested (virtually zero-true 0 impossible) Zero EMF Controls/Thermostat is required for operation Nuheat Floor sensing thermostat Conduit is not required for Power Leads Conduit is not required for Power Leads Spacing between runs (inches) Heated SF Watts Per SF BTUs/SF/Hr 3 19 12 41 - Reviews