- Overview
-
Nuheat standard size pre-built floor heat mats come ready to fit the room and will keep almost any flooring at a warm and comfortable temperature that you set on the Nuheat thermostat control.
You can use more than one Nuheat mat combined to fit any room size or shape, up to the amp limit of the thermostat (150 SF for 120v / 300 SF for 240v Mats). All Mats connect to the Thermostat, not to each other.
Nuheat mats are like electric blankets - you choose the size or sizes to cover your desired floor area - or ask for our expert assistance at NO OBLIGATION. The mats cannot be cut or altered - so choose the right size - we can help.
- Product Details
Width of heating area Feet 4' Ft. Feet Length of heating area Feet 2.5' Ft. Feet Heated Area 10 SF (Sq. Ft. Square Feet) Width of heating area inches 48" in. Inch Length of heating area inches 30" in. Inch Mat Size 1 in inches 48" inches x 30" inches Mat Size 2 in Feet 4' Ft. Feet x 2.5' Ft. Feet Mat Style Fiber mat. Heating wire sandwiched completely in the material. Requires thinset mortar under mat to attach to floor. Custom Mat Options Yes, custom mats available upon request Safety Listed in USA & Canada : UL 1693 & CAN/CSA C22.2 No. 130-03 Nuheat is UL (Underwriters Laboratory) File No. E317395 Packaging Easy Open Cardboard - no frustration Color Gray fiber mat-silver ground shield Acceptable Floor Coverings Tile, Stone,Granite, Marble, Slate, Engineered wood, Laminate Made In USA Made in Canada from a majority of USA components. - How to Install
Nuheat mats are squares and rectangles in over 120 sizes and will fit any room regardless of shape or size. When installing your floor, the heating mats are set in a thin spread of mortar (the same bonding materials used to lay your tile floor). Once your subfloor is prepared, and you have installed the Nuheat mat, apply another layer of thinset or mortar, lay your tile as usual and make the final connection to the Nuheat Thermostat control.
Laminate & Engineered Hardwood: simply install the Nuheat mat as above. Next, cover the Nuheat mat with at least 1/4 inch mortar or floor leveling cement. Once the mortar has cured, install your floor according to the flooring manufacturer's instructions.
Nuheat Mats Instruction Manual /media/Nuheat-Mats-installation-instructions-Manual-current.pdf Nuheat Mats Installation Video Maximum Circuit Load 15 Amps Maximum Circuit Overload Protection 20 A Breaker. GFCI Protection Required (Ground Fault Circuit Interrupter) Required for each circuit - INCLUDED in Thermostat Control Circuit Breaker & supply wire Recommended (must follow local codes) See chart Electrical Box Size (Where Mats connect to Thermostat) Extra-deep single-gang box for 1 or 2 leads, Or 4" square deep box for 3 cables (extra room needed for Wire, wire nuts, control) Heating Elements (Dual Wire) Oxygen-free copper or nickel-copper Full Length End-to-End ground wire Yes. Heating Wire Insulation wire construction Copper/Copper Alloy Heating wire insulated with ETFE and surrounded with protective Stainless steel ground shield. Repairable Heating Wire Yes, Wire can be repaired. Repair kits and assistance available. Expected Floor Temperature Dependent on Many factors, insulation recommended. Read More Skill Level : D-I-Y Simple for Install, PRO for Electric Installation only by qualified persons. Electrician recommended for wiring. Read More Shower Installation Permitted (USA) Yes, can be installed in a tiled shower. Read More Installation Layout Map customized for my project Yes - Click here to read more Insulation Recommended Yes; under slabs or framed floors. Cork or similar on top of Concrete Subfloor as thermal break Indoor Installation Only INTERIOR floor heating Application only. Embedded in Mortar only Installation On Sub Floor on TOP of Sub Floor (Plywood, backer board, concrete) Distance from Wax Ring at toilet flange install 4 - 6 inches away; can be under front of toilet. Approx 20" from wall Trowel Size recommended minimum 3/8" x 1/4". Works for most ceramic tile; verify with tile/mortar manufacturer Trowel type Recommended Heavy Duty Plastic PRO-Trowel Minimum Bend Radius 0.625" inch Cut Warning No. Never cut the heating elements to shorten Minimum Installation Temperature 50 Degrees F / 10 Degrees C - Specifications
Voltage 120 VAC How to choose 120 or 240 Volt Same Energy efficiency & same Watts/SF. More Sq Footage per circuit with 240v Amp Draw (this Mat) 1.0 Watts Per SF 12 Watts per Sq Foot Wattage : total watts for this mat 120 watts Heat Output BTUs per SF 41 BTU per Sq Ft/Hour Heating Power : Total BTU's 410 BTU Total Manufacturer Nuheat Industries Ltd. Brands Nuheat Power Lead Type TEW Wire with Stainless Steel ground braid rated to 105 C and 300v max. Power Lead Length 10 Feet Power Lead Wire Gauge (varies by heated area) 16 AWG Product Thickness .083 (1/8") plus thinset Under Heating Wire Spacing within Mat 2.0" inches Weight 3.0000 Ohms Reading (resistance value) for Wht/Blk or Blue/Blk wires 120 ohms Controls/Thermostat is required for operation Nuheat Floor sensing thermostat - Reviews