- Overview
-
Product Information
- Easy to install in every size or shape room
- Safe enough for a Shower Floor and Seat Installation *NEW in 2010*
- Eliminate Electro Magnetic Fields with Active Shielding & Twin-wire technology
- Durable 3-layer protection with a 25 year warranty
- Flexible installation for curves and angles and available in 120VAC and 240VAC
- Armored 3-wire power lead - no return wire from the end 1 Connection
- Oxygen-free heating elements for long life
- High Performance ETFE insulation
- Protected by woven stainless steel braid
- Strengthened with Polyurethane Jacket for maximum impact & cut resistance
- Safe grounded from end to end and UL listed in USA & Canada
SunTouch WarmWire is the affordable alternative to SunTouch Floor Heating Mats.
WarmWire floor heating cables are similar in construction and provide heat just like SunTouch mats, but install differently and cost less. Simply place and attach the WarmWire strap to the subfloor and weave the wire back and forth between straps to create your own heated area. Cover with thin-set or self-leveling mortar and finish with almost any floor covering. You weave the wire onto the subfloor while maintaining the spacing of wires.
WarmWire is the best there is.
- Product Details
WarmWire = Zero EMF
An emerging issue in the electric radiant heat industry is EMF (electromagnetic field) radiation. SunTouch pioneered and sells only ZERO EMF products constructed with active dual wire EMF-canceling technology.
All WarmWire products use a complex wire construction with two heating elements in parallel with an added and patented helical twist to eliminate EMF. Other electric radiant floor heating companies sell single-wire systems that release high levels of EMF when compared to WarmWire.
What is EMF? Electromagnetic fields (EMF) come from all electrical appliances, but studies show an average American's daily exposure is less than 1 unit (mG) of EMF. But. when you sit on an unshielded electric radiant floor, you may be exposed to 20, 40, or more times the average daily exposure. This Data comes from Independent testing. Read More Here
Is limiting exposure to EMF important? No one is certain. The World Health Organization says the data is inconclusive to date, but continues their research. We provide this EMF information because it is important to some people, not to frighten you or exaggerate any risk.
For many years customers have chosen WarmWire Zero EMF systems, but we leave the choice to you after explaining what we do know.
Width of heating area Feet Variable - you determine layout width, length, shape Length of heating area Feet Variable - you determine layout width, length, shape Heated Area 35 SF (Sq. Ft. Square Feet) Length of heating area inches 1980" in. Inches Mat Style Heating Cable secured to floor using Metal Cable Strap (track). Strap secured to floor with tape,screws or glue Custom Mat Options None. Standard lengths only. No customization Safety Listed in USA & Canada : UL 1693 & CAN/CSA C22.2 No. 130-03 UL (Underwriters Laboratory) File No. E185866 Packaging Easy Open Cardboard - no frustration. Easy to dispense wire from box Color Clear flexible Polyurethane Coating Jacket over Stainless Steel braid WarmWire Strap Qty to Order 1 (based on 2.5") Acceptable Floor Coverings Natural Stone,Tile, Laminate, Engineered Woods, Carpet, Vinyl, Linoleum, Solid Hardwood (if you use sleepers) Made In USA Made in USA - How to Install
SunTouch WarmWire Instruction Manual /media/SunTouch-WarmWire-Installation-Manual-Current-WYF.pdf WarmWire Installation Video Maximum Circuit Load 15 Amps Maximum Circuit Overload Protection 20 A Breaker. GFCI Protection Required (Ground Fault Circuit Interrupter) Required for each circuit - INCLUDED in SunStat Control Circuit Breaker & supply wire Recommended (must follow local codes) See chart Electrical Box Size (Where Mats connect to Thermostat) Extra-deep single-gang box for 1 or 2 leads, Or 4" square deep box for 3 cables (extra room needed for Wire, wire nuts, control) Heating Elements (Dual Wire) Oxygen-free copper or nickel-copper Full Length End-to-End ground wire Yes. Heating Wire Insulation wire construction ETFE Fluoropolymer, Stainless Steel Ground Braid shield and Outside layer of Clear Polyurethane Repairable Heating Wire Yes, Wire can be repaired. Repair kits and assistance available. Expected Floor Temperature Dependent on Many factors, insulation recommended. Read More Skill Level : D-I-Y Simple for Install, PRO for Electric Running Cable more difficult + more time than MATS. Installation only by qualified persons. Electrician recommended for wiring. Read More Shower Installation Permitted (USA) Yes, can be installed in a tiled shower. Read More Installation Layout Map customized for my project Yes - see examples. We provide Layout Maps only for MATS Insulation Recommended Yes; under slabs or framed floors. Cork or similar on top of Concrete Subfloor as thermal break Indoor Installation Only INTERIOR floor heating Application only. Embedded in Mortar only Installation On Sub Floor on TOP of Sub Floor (Plywood, backer board, concrete) Distance from Wax Ring at toilet flange install 4 - 6 inches away; can be under front of toilet. Approx 20" from wall Trowel Size recommended minimum 3/8" x 1/4". Works for most ceramic tile; verify with tile/mortar manufacturer Trowel type Recommended Heavy Duty Plastic PRO-Trowel Minimum Bend Radius 1/2" 0.50 inch Cut Warning No. Never cut the heating elements to shorten Minimum Installation Temperature 50 Degrees F / 10 Degrees C - Specifications
Voltage 120 VAC How to choose 120 or 240 Volt Same Energy efficiency & same Watts/SF. More Sq Footage per circuit with 240v Amp Draw (this Mat) 3.5 Watts Per SF 12 Watts per Sq Foot Wattage : total watts for this mat 420 watts Heat Output BTUs per SF 41 BTU per Sq Ft/Hour Heating Power : Total BTU's 1435 BTU total Manufacturer Watts Radiant Brands SunTouch Floor Warming Power Lead Type Armored, NEC color code, Single point connection at 1 corner of mat. No return wire like inferior products Power Lead Length 10 Feet Power Lead Wire Gauge (varies by heated area) 18 AWG Warranty from Manufacturer 25 Year backed by 140 year old USA Manufacturer Product Thickness 3/16" or a little more Heating Wire Spacing within Mat 2" - 2.5" - 3" on center Weight 4.2500 Ohms Reading (resistance value) for Wht/Blk or Blue/Blk wires 29-36 ohms ZERO* EMF (Electro Magnetic Field) Tested (virtually zero-true 0 impossible) Yes. Verified by Independent Testing Laboratory as ultra low. REET test Controls/Thermostat is required for operation SunStat Floor sensing thermostat Conduit is not required for Power Leads Conduit is not required for Power Leads Spacing between runs (inches) Heated SF Watts Per SF BTUs/SF/Hr 2 28 15 51 2.5 35 12 41 3 35 12 41 - Reviews