Warmup Commercial Grade Heating Cable (Constant Wattage), 240V 93'L, 500W, 2.1 amps. Covers 24-39 sq ft of heated area.

Write the first review
SKU: WODH-240/500-C

Warmup’s In-Slab WODH heating cable is the best choice for primary heating applications before your slab is poured.

Warmup’s most durable cable withstands the rigors of a concrete pour thanks to its advanced fluoropolymer jacket and high output of 5.5 Watts per linear foot. Thanks to its structure and build, it cancels out all electro-magnetic field interference. The cable is typically tied to a lightweight mesh or rebar and embedded in a concrete pour, but it can also be used for thermal storage and frost heave applications and installed in dirt or sand beds.

It is suitable for primary heating in residential and commercial environments. The In-Slab Cable should be laid at least 2″ apart and a 2″ deep within the slab. After the cable is in place, carefully pour cementitious material over the In-Slab Cable to a depth of at least 2″.

Once installed within the slab, you can effectively heat any floor covering or simply leave the bare or polished concrete as your finished floor.

  • Designed for 240V and works with 208 & 277 VAC
  • Spaced at 3”, 4” or 5” for in-slab heating with output of 12W, 17W and 21W per sqft.
  • Spaced at 6” to 8” for Frost Heave protection: outputs of 7W to 10W/sqft.
  • Dual Conductor, one-point connection.

Instructions + Video

Indoor / Outdoor

Indoor

National Electric Code reference

Safety listed by CSA in USA & Canada to UL specifications

Minimum Depth

1-3/8"

Specifications

EMF (Electro Magnetic Field) Dual Conductor cancels EMF
Ohms Reading (resistance value) 114.3
Power Lead Length 16 Ft Long
Power Lead Type Jacketed 3-wire
Thickness 3/8" Dia
Voltage 208 - 277 (nominal 240V)
Wattage per SF 21 - 13 (3-5" spacing)
Watts per Sq Ft 17 W/SF
Spacing of Heating Wire Variable-See chart
Manufacturer Warmup
BTUs/SF/Hr 1 71
BTUs/SF/Hr 2 55
BTUs/SF/Hr 3 44
Spacing between runs 1 3"
Spacing between runs 2 4"
Spacing between runs 3 5"
Heated SF 1 24
Heated SF 2 30
Heated SF 3 39
Watts Per SF 1 20.8
Watts Per SF 2 16.5
Watts Per SF 3 13
Heated Area in Sq Ft typical 30 SF @ 4"

More Details

Canadian Electric Code reference Safety listed by CSA in USA & Canada to UL specifications
Safety Listing Safety listed by CSA in USA & Canada to UL specifications
Warranty from Manufacturer 10 Year Warranty
Amp Draw 2.1
Total Watts 500
Wire Construction Copper conductor resistance cable with FPE Insulation and Metal Sheathing. 3/8” thickness.
Cable Length 93

Reviews

Write Your Own Review
You're reviewing: Warmup In-Slab Heat Cable, 240V, 437'L, 2400W, 10.0A, Heats 105-182 Sq Ft
Loading...

You submitted your review for moderation.