SunTouch UnderFloor is a safe and efficient radiant electric floor heating system retrofitting an existing cold floor with heat without disturbing the existing floor covering.
UnderFloor is for interior applications only and is intended only for installation under an existing wood subfloor (accessed from underneath via crawl space, basement, or garage ceiling) in residential and light commercial installations.
Insulation is essential after mats are installed into joist spaces.
We recommend SunTouch UnderFloor Mats be installed in all areas where floor warming is desired; the floor is only warm directly over an installed mat.
If UnderFloor is being installed to heat the space, first perform a heat loss calculation to determine the amount of BTUs required to heat the space.
Instructions + Video
SunTouch 1201216U2ST UnderFloor 16" x 12' long 120V 1.3A Installation Manual
INTERIOR floor heating Application only. Never embedded in Mortar.
Installation Steps
Step 1 Unroll mat and staple 1 side to side of first joist so foil will be 2 from Sub floor above and hangs down like a curtain. | |
Step 2 Staple other side to opposite joist. Each mat must fit within a single joist bay. | |
Step 3 Mount Electrical boxes and connect mats in parallel to power in junction boxes. Follow applicable building and electrical codes, using conduit to electrical boxes as required. 15 amps maximum per thermostat. If you have only a few mats, the power leads may reach the thermostat without a Junction Box. | |
Step 4 Connect the SunStat thermostat and test the system. Then install fiberglass insulation batts (R-11 to R-19) up to the mats. Insulation must be installed at the ends of the joist bays vertically or 6 inches after the mat ends. |
Kitchen Layout Example Using UnderFloor Mats
Each electric UnderFloor heating mat is designed to be installed in a single joist bay. The heating mats cannot be cut shorter to fit a shorter joist bay or altered in any way. Do not try to fill multiple joist bays with 1 mat. However, multiple mats may be installed in a joist bay where there are obstructions (such as cross bracing) as long as they do not overlap or touch. In this layout, four 9.5'x16" and eight 4'x16" mats are required to warm the floor area. |
The heat mats are wired together in parallel (not in series) in junction boxes below the floor, then an electric wire is fed over to the SunStat control.
Mat lengths should be selected so they fit completely within each bay and allow for the easiest wiring. When all the power leads start on one side, it will be easy to wire them together in the junction boxes. Code requires junction boxes to remain accessible at conclusion of the job.
dd50° Degrees F / 10° Degrees C
Mats or Wire | Supply Wire | Breaker | |||
VAC | total amps | (AWG*) | qty | type | rating |
120 | up to 12 amps | 14 | 1 | single pole | 15 or 20 A |
120 | up to 15 amps | 12 | 1 | single pole | 20 A |
240 | up to 12 amps | 14 | 1 | double pole | 15 or 20 A |
240 | up to 15 amps | 12 | 1 | double pole | 20 A |
* Recommended only. Follow local codes for wire gauge size.
ETFE Fluoropolymer, metal shield and Radiant Foil
15 Amps
20 A Breaker.
See manual; 2-8" from most. Do not let foil touch any metal
Specifications
UPC | 840213080686 |
---|---|
Heating Power Output Total | 187 BTU total |
Heating Power Output per Hour (BTU) | 34 BTU per Sq Ft/Hour |
EMF (Electro Magnetic Field) | Yes. Verified by Independent Testing Laboratory as ultra low. REET test |
Ohms Reading (resistance value) | 247-302 ohms |
Power Lead Wire Gauge | 18 AWG |
Power Lead Type | Armored, NEC color code, Single point connection at 1 corner of mat. No return wire like inferior products |
Thickness | 0.125 (less than 1/8") |
Voltage | 120 VAC |
Wattage per SF | 10 |
Manufacturer | Watts Radiant |
Power Lead Length | 10 Feet |
More Details
Brand Name | SunTouch |
---|---|
Warranty from Manufacturer | 25 Year backed by 140 year old USA Manufacturer |
What's In The Box | Mat, Detailed Installation Manual. |
Amp Draw | 0.4 |
Safety Listing | UL (Underwriters Laboratory) Listed for U.S. and Canada under UL 1673 and CAN/CSA C22.2 No. 130-03, File No. E185866 |
Total Watts | 55 watts |
Size in Inches | 12" x 66" (12x66 inches) |
Size in Feet | 1' x 5.5' (1x5.5 feet) |
Size in Meters | 0.3m x 1.68m (0.3x1.68 meters) |
Acceptable Floor Coverings | Natural Stone,Tile, Laminate, Engineered Woods, Carpet, Vinyl, Linoleum, Solid Hardwood |
Reviews
Customer Reviews
Most time consuming part of the install was breaking off all the ends of the screws protruding thru the floor that were securing the tile underlayment. The actual product install was easy so someone with even a moderate level of "handyman" experience could handle it.
We love the floor heat so much that when we started a walkout basement project we added heat below the tile in the entry and bathroom. We're still in the remodeling phase but the system is in and waiting to be started. We're very glad we did, it will be such a big addition to a beautiful floor and project.